MQ-5 Methane LPG Propane Gas Sensor is a high-sensitivity chemical gas detection breakout board specifically designed for detecting natural gas, methane (CH4), liquefied petroleum gas (LPG), and town coal gas. Utilizing an optimized tin dioxide (SnO2) semiconductor element enclosed within an explosion-proof stainless steel double-screen hood, the sensor offers exceptionally high sensitivity to methane and town gas while effectively rejecting interference from alcohol, cooking fumes, and cigarette smoke. Built with an onboard LM393 voltage comparator, multi-turn calibration trimmer, and dual LED indicators, the module provides simultaneous analog (A0) voltage output for precision microcontroller ADC monitoring and digital (D0) TTL switching output for direct alarm relay activation.

Key Features:
  • High Sensitivity to Methane & Natural Gas: Engineered with high selectivity to natural gas and methane across 200 to 10,000 ppm with robust noise rejection.
  • Dual Signal Output Interfaces: Simultaneous linear analog voltage (A0) for quantitative ppm measurement and digital TTL switching output (D0) for threshold alarm actuation.
  • Onboard LM393 Voltage Comparator: Guarantees stable, noise-free TTL digital switching with adjustable trigger threshold calibrated via the onboard multi-turn potentiometer.
  • Dual Diagnostic LEDs: Integrates a power indicator LED and a digital switching status LED that illuminates immediately when the gas threshold is exceeded.
  • Anti-Explosion Double-Layer Mesh: Heavy-duty stainless steel mesh enclosure isolates the internal heating filament from surrounding combustible gas mixtures.
Technical Specifications:
  • Operating Supply Voltage: 5.0V ± 0.1V DC
  • Heater Operating Voltage: 5.0V ± 0.1V AC/DC
  • Operating Current Consumption: ≤ 160 mA (heater active)
  • Heater Power Consumption: ≤ 800 mW
  • Heater Resistance: 31 Ω ± 3 Ω
  • Target Gases: Natural Gas, Methane (CH4), Liquefied Petroleum Gas (LPG), Town Coal Gas
  • Detection Concentration Range: 200 ppm to 10,000 ppm
  • Sensitivity Ratio (Rs in Air / Rs in 1000ppm CH4): ≥ 5
  • Response Time: ≤ 10 seconds
  • Recovery Time: ≤ 30 seconds
  • Preheating Warm-up Time: > 24 hours (initial burn-in), > 2 minutes (standard power-up)
  • Operating Temperature Range: -10°C to 50°C
  • Operating Relative Humidity: ≤ 95% RH (non-condensing)
Mechanical Specifications:
  • PCB Material: Double-sided FR-4 glass-epoxy board with high-durability solder mask
  • Sensor Enclosure: Explosion-proof stainless steel double-mesh cap with nickel-plated base
  • Mounting Holes: 4 × M3 corner mounting holes for chassis attachment
  • Connector Type: Standard 4-pin 2.54mm pitch right-angle male header
  • Net Weight: Approximately 8 g
Dimensions:
  • PCB Length: 32.0 mm
  • PCB Width: 20.0 mm
  • Overall Height: 22.0 mm
  • Mounting Hole Diameter: 3.2 mm
  • Pin Pitch: Standard 2.54 mm (0.1 inch)
Pinout and Wiring:
  • Pin 1 (VCC): +5V DC regulated power supply input
  • Pin 2 (GND): Ground reference connection (0V)
  • Pin 3 (DO): Digital switching output (active LOW TTL logic, directly triggers MCU GPIO or alarm buzzer)
  • Pin 4 (AO): Analog voltage output (0V to 5V DC, proportional to detected combustible gas concentration)
Datasheet Reference:
  • Sensing Element: Hanwei Electronics / Winsen MQ-5 Semiconductor Gas Sensor Datasheet
  • Comparator Subsystem: Texas Instruments LM393 Dual Comparator Specification
  • Sensing Methodology: Chemiresistive SnO2 semiconductor surface oxidation with reducing methane molecules
Commonly Used in:
  • Domestic gas leak detectors, kitchen safety monitors, and town gas utility meters.
  • Industrial gas boiler rooms, pipeline distribution manifolds, and CNG vehicle workshops.
  • Biogas digester monitoring systems and underground utility trench surveillance.
  • Smart home safety alarms and educational microcontroller robotics projects.
Applications:
  • Natural Gas Leak Detection: Real-time detection of methane leaks around residential and commercial gas piping.
  • Automated Gas Valve Actuation: Triggering electric motorized ball valves or solenoid cutoffs upon gas detection.
  • IoT Kitchen Safety Node: Broadcasting telemetry over Wi-Fi (ESP32) to cloud monitoring platforms and home automation hubs.
  • Biogas Generation Telemetry: Tracking combustible methane concentration in agricultural anaerobic digesters.
Equivalent Models:
  • Winsen MQ-5: Standard modular equivalent providing identical electrical ratings and target gas sensitivity.
  • MQ-4 Gas Sensor Module: Specialized methane sensor offering higher specific sensitivity to natural gas with slightly lower LPG cross-sensitivity.
  • MQ-6 Gas Sensor Module: Hydrocarbon sensor optimized primarily for heavier LPG and propane gases rather than lighter methane.
  • Figaro TGS2611: High-selectivity Japanese semiconductor methane sensor featuring high filter efficiency against volatile organic compounds.
Package Includes:
  • 1 × MQ-5 Methane LPG Propane Gas Sensor
Weight 10 g
Dimensions 35 × 20 × 20 mm
INPUT VOLTAGE

5v

Questions and Answers

No questions have been asked about this product yet. Be the first!


Ask a Question

Average Rating
0.00
0 Reviews
5 Star
0%
4 Star
0%
3 Star
0%
2 Star
0%
1 Star
0%

Be the first to review “MQ-5 Methane LPG Propane Gas Sensor”

You must be logged in to post a review.

Reviews

No reviews yet. Be the first to share your experience!

You may also like…

₹110.00
Hi, How can I help you today?
Chat Assistant