Back to Category
Shop By Departments

MQ-135 Air Quality Sensor Module

₹110.00

In stock ?

In stock

Category: Brand:

MQ-135 Air Quality Sensor Module is a versatile chemical gas sensor breakout board engineered for indoor air quality (IAQ) monitoring and hazardous gas detection. Built with a broad-spectrum tin dioxide (SnO2) semiconductor sensing element housed beneath an explosion-proof stainless steel mesh, the sensor demonstrates high sensitivity to harmful gases including ammonia (NH3), nitrogen oxides (NOx), alcohol, benzene, smoke, and carbon dioxide (CO2). The breakout board integrates an onboard LM393 dual voltage comparator, multi-turn threshold trimmer potentiometer, and dual status LEDs, providing simultaneous analog voltage output (A0) for quantitative air pollution index calculation and digital TTL output (D0) for immediate alarm actuation.

Key Features:
  • Broad-Spectrum Hazardous Gas Detection: Highly sensitive to ammonia, NOx, alcohol, benzene, smoke, and volatile organic compounds across 10 to 1,000 ppm.
  • Dual Signal Outputs: Delivers continuous analog voltage (A0) proportional to ambient pollution levels and digital TTL output (D0) for threshold triggering.
  • Onboard LM393 Voltage Comparator: Provides clean, jitter-free TTL switching signals with sensitivity threshold calibrated via the onboard multi-turn potentiometer.
  • Dual Diagnostic LEDs: Features an onboard power indicator LED and a digital switching status LED that illuminates when air quality degrades past the setpoint.
  • Explosion-Proof Stainless Steel Shield: Heavy-duty stainless steel double-mesh cap isolates internal heating elements from ambient atmosphere while allowing free gas diffusion.
Technical Specifications:
  • Operating Supply Voltage: 5.0V ± 0.1V DC
  • Heater Operating Voltage: 5.0V ± 0.1V AC/DC
  • Operating Current Consumption: ≤ 160 mA (heater active)
  • Heater Power Consumption: ≤ 800 mW
  • Heater Resistance: 31 Ω ± 3 Ω
  • Target Gases: Ammonia (NH3), Nitrogen Oxides (NOx), Alcohol, Benzene, Smoke, Carbon Dioxide (CO2)
  • Detection Concentration Range: 10 ppm to 1,000 ppm
  • Sensitivity Ratio (Rs in Air / Rs in 50ppm NH3): ≥ 5
  • Response Time: ≤ 10 seconds
  • Recovery Time: ≤ 30 seconds
  • Preheating Warm-up Time: > 24 hours (initial burn-in), > 5 minutes (standard power-up)
  • Operating Ambient Temperature: -10°C to 50°C
  • Operating Relative Humidity: ≤ 95% RH (non-condensing)
Mechanical Specifications:
  • PCB Material: Double-sided FR-4 glass-epoxy circuit board with protective solder mask
  • Sensing Element Housing: Explosion-proof stainless steel double-mesh cap with nickel-plated base
  • Mounting Holes: 4 × M3 mounting screw holes for chassis integration
  • Interface Connector: 4-pin 2.54mm pitch right-angle male header
  • Net Weight: Approximately 8 g
Dimensions:
  • PCB Length: 32.0 mm
  • PCB Width: 20.0 mm
  • Overall Height: 22.0 mm
  • Mounting Hole Diameter: 3.2 mm
  • Pin Pitch: Standard 2.54 mm (0.1 inch)
Pinout and Wiring:
  • Pin 1 (VCC): +5V DC regulated power supply input
  • Pin 2 (GND): Ground reference connection (0V)
  • Pin 3 (DO): Digital switching output (active LOW TTL logic, directly triggers MCU GPIO or alarm buzzer)
  • Pin 4 (AO): Analog voltage output (0V to 5V DC, proportional to detected hazardous gas concentration)
Datasheet Reference:
  • Sensing Element: Hanwei Electronics / Winsen MQ-135 Air Quality Gas Sensor Datasheet
  • Comparator Subsystem: Texas Instruments LM393 Dual Differential Comparator Specification
  • Sensing Principle: Chemiresistive SnO2 semiconductor conductivity modulation via reducing and toxic gas adsorption
Commonly Used in:
  • Smart home air purifiers, fresh air ventilation units, and residential HVAC systems.
  • Office building air quality monitors, school classroom pollution meters, and conference room ventilation nodes.
  • Agricultural poultry farms, livestock barns, and waste management ammonia monitoring stations.
  • Educational Arduino, ESP32, and Raspberry Pi environmental IoT projects.
Applications:
  • Indoor Air Quality (IAQ) Indexing: Measuring composite indoor pollution levels and calculating qualitative air freshness ratings.
  • Automated Air Purifier & Vent Actuation: Triggering exhaust fans and HVAC filtration stages when smoke or ammonia levels rise.
  • IoT Environmental Telemetry: Streaming ambient air quality metrics over Wi-Fi (ESP8266/ESP32) to cloud dashboards.
  • Ammonia Hazard Monitoring: Detecting toxic ammonia vapors in agricultural livestock enclosures and chemical handling areas.
Equivalent Models:
  • Winsen MQ-135: Standard direct component replacement providing identical pinout, heating parameters, and sensitivity characteristics.
  • Winsen MP-135: Miniature flat-pack semiconductor air quality sensor featuring lower power heater consumption for portable monitors.
  • Sensirion SGP30: Multi-pixel digital metal oxide sensor offering calibrated TVOC and eCO2 output over I2C communication.
  • ScioSense CCS811: Digital ultra-low power VOC and equivalent CO2 sensor with onboard MCU for indoor air quality logging.
Package Includes:
  • 1 × MQ-135 Air Quality Sensor Module
Weight 10 g
Dimensions 32 × 20 × 20 mm
INPUT VOLTAGE

5v

Questions and Answers

No questions have been asked about this product yet. Be the first!


Ask a Question

Average Rating
0.00
0 Reviews
5 Star
0%
4 Star
0%
3 Star
0%
2 Star
0%
1 Star
0%

Be the first to review “MQ-135 Air Quality Sensor Module”

You must be logged in to post a review.

Reviews

No reviews yet. Be the first to share your experience!

₹110.00
Hi, How can I help you today?
Chat Assistant