MAX30102 Heart Rate and Pulse Oximeter Sensor Module is an integrated optical biosensor breakout board engineered for non-invasive heart rate (pulse) and peripheral capillary oxygen saturation (SpO2) monitoring in fitness, medical prototyping, and wearable biomedical electronics. Built around the high-sensitivity Analog Devices / Maxim Integrated MAX30102 sensor chip, the module integrates dual internal light-emitting diodes (660nm red LED and 880nm infrared LED), a high-resolution photodetector, low-noise analog front-end electronics with ambient light cancellation, and a 16-bit sigma-delta ADC. Featuring an onboard 3.3V / 1.8V low-dropout voltage regulation subsystem and level-shifting circuitry on a compact matte-black PCB, it communicates seamlessly over a standard I2C digital bus with microcontrollers including Arduino, ESP32, STM32, and Raspberry Pi.
Key Features:
- Dual-Wavelength Optical Biometrics: Incorporates precision 660nm red and 880nm infrared light sources for accurate pulse oximetry (SpO2) and photoplethysmogram (PPG) acquisition.
- Integrated Low-Noise Optical System: Internal glass cover optimizes optical path geometry while rejecting ambient room lighting and 50Hz/60Hz artificial flicker.
- High-Resolution Digital Conversion: Built-in 16-bit sigma-delta analog-to-digital converter with selectable sample rates from 50 sps to 3200 sps and 32-sample deep FIFO buffer.
- Wide Microcontroller Compatibility: Onboard dual LDO regulators provide 1.8V sensor core supply and 3.3V logic level compatibility for 3.3V and 5V development boards.
- Ultra-Low Power Sleep Modes: Features programmable shutdown current under 0.7 µA, making it ideal for battery-operated fitness trackers and portable health monitors.
Technical Specifications:
- Module Input Supply Voltage (VIN): 3.3V to 5.0V DC
- Sensor Core Operating Voltage: 1.8V DC (regulated internally)
- LED Supply Operating Voltage: 3.3V DC (regulated internally)
- Peak Operating Current: ≤ 20 mA (during dual-LED optical burst)
- Standby Power-Down Current: 0.7 µA typical
- Red Light Wavelength: 660 nm ± 5 nm
- Infrared (IR) Light Wavelength: 880 nm ± 10 nm
- ADC Resolution: 16-bit sigma-delta
- Sampling Rate Selection: 50 to 3200 samples per second (sps)
- Digital Interface: Standard I2C Fast-Mode (up to 400 kHz), Fixed 7-bit Address 0x57
- Onboard Buffer: 32-sample FIFO (First-In, First-Out) memory structure
- Operating Temperature Range: -40°C to 85°C
Mechanical Specifications:
- PCB Substrate: Double-sided matte black FR-4 with gold-immersion contacts
- Optical Cover: Integrated protective glass aperture shielding photodetector and LEDs
- Mounting Holes: 2 × M2 mounting holes for chassis or finger clip fixation
- Connector Type: Standard 5-pin 2.54mm pitch right-angle/straight pin header
- Net Weight: Approximately 3 g
Dimensions:
- PCB Length: 20.5 mm
- PCB Width: 15.0 mm
- Overall Height: 3.5 mm
- Mounting Hole Diameter: 2.1 mm
- Pin Pitch: Standard 2.54 mm (0.1 inch)
Pinout and Wiring:
- Pin 1 (VIN): Power supply input (3.3V to 5.0V DC)
- Pin 2 (GND): System ground connection (0V)
- Pin 3 (SCL): I2C serial clock bus line (connects to MCU SCL)
- Pin 4 (SDA): I2C serial data bus line (connects to MCU SDA)
- Pin 5 (INT): Active-LOW programmable hardware interrupt pin (signals new FIFO data or threshold alarm)
Datasheet Reference:
- Sensor IC: Analog Devices / Maxim Integrated MAX30102 High-Sensitivity Pulse Oximeter and Heart-Rate Sensor Datasheet
- I2C Communication Specification: Philips / NXP Standard 7-bit I2C Bus Protocol with multi-read burst modes
- Optical Calibration Application Note: Maxim Integrated AN6409 – SpO2 and Heart Rate Biosensor Design Guidelines
Commonly Used in:
- Smart wearable fitness bands, athletic smartwatches, and biometric activity trackers.
- Portable fingertip pulse oximeter instruments and medical diagnostic prototypes.
- Home patient remote telemetry gateways and telemedicine health stations.
- Biometric human-machine interface (HMI) devices and university biomedical engineering labs.
Applications:
- Continuous Heart Rate Tracking: Measuring beats per minute (BPM) from finger arterial blood volume fluctuations.
- Peripheral Blood Oxygenation (SpO2): Calculating arterial oxygen saturation ratio using differential red vs. infrared absorption spectroscopy.
- Sleep Quality Telemetry: Monitoring nocturnal hypoxemia and respiratory irregularities via Bluetooth/Wi-Fi connected wearables.
- Stress & Heart Rate Variability (HRV): Capturing raw PPG pulse waveforms for algorithmic analysis of sympathetic and parasympathetic nervous states.
Equivalent Models:
- MAX30100 Sensor Module: Predecessor biosensor featuring slightly lower ADC dynamic range, distinct internal register mappings, and separate power rail requirements.
- MAX30105 Optical Sensor Module: Triple-wavelength variant adding a 537nm green LED optimized specifically for wrist-based skin penetration and particle detection.
- Pulse Sensor Amped: Discrete analog photoplethysmogram sensor outputting raw analog pulses rather than calibrated digital I2C dual-wavelength data.
- SparkFun Micro Bio Sensor MAX30101: Qwiic-compatible miniature breakout offering identical optical performance in an ultra-miniature form factor.
Package Includes:
- 1 × MAX30102 Heart Rate and Pulse Oximeter Sensor Module
- 1 × 5-Pin Male Header Strip


Reviews