HDS10 Condensation Sensor is a high-reliability organic polymer electrolytic condensation and high-humidity detection sensor engineered to provide an exponential resistance shift under high-humidity and near-condensation (dew-point) atmospheric conditions. Exhibiting a steep, sharp resistance increase once relative humidity breaches 90% RH and approaching near-insulator impedance during true condensation (≥ 98% RH), the HDS10 functions as an ultra-sensitive electronic early-warning cutoff switch against damaging water droplet formation. Featuring high response speed, excellent moisture recovery characteristics, and high resistance to airborne chemical contamination, it is the industry-standard condensation protection sensor for laser optical heads, high-end video cameras, cold-storage refrigeration, and industrial climate chambers.
Key Features:
- Steep Condensation Response: Impedance shifts dramatically by orders of magnitude from standard kilohm levels up into megohms as humidity approaches the condensation threshold (> 90% RH).
- Fast Recovery Characteristics: Desorbs moisture rapidly as environmental conditions normalize, returning to baseline resistance within seconds without calibration drift.
- High Chemical & Dust Contamination Immunity: Sealed organic polymer substrate resists degradation from common atmospheric pollutants, smoke, and fine dust.
- Zero Standby Power Dissipation: High baseline resistance and micro-watt consumption make it ideal for power-sensitive battery-operated optical equipment.
- Compact Low-Profile Form Factor: Miniature footprint allows direct flush mounting next to sensitive optical lenses, camera CCD sensors, and chiller heat exchangers.
Technical Specifications:
- Operating Supply Voltage: 0.8 V AC RMS (Max: 1.0 V AC RMS, 50 Hz to 1 kHz)
- Operating Frequency: 50 Hz to 1000 Hz AC (Do not apply DC bias)
- Power Dissipation: ≤ 0.2 mW
- Nominal Resistance (at 75% RH): ≤ 2.0 kΩ
- Nominal Resistance (at 93% RH): ≥ 6.8 kΩ
- Nominal Resistance (at 98% RH – Condensation Threshold): ≥ 100.0 kΩ
- Nominal Resistance (True Condensation): > 200.0 kΩ
- Response Time (Dewing): ≤ 10 seconds
- Response Time (Recovery / Desorption): ≤ 15 seconds
- Operating Temperature Range: +1°C to +80°C
- Storage Environment: -20°C to +60°C, < 95% RH non-condensing
Mechanical Specifications:
- Sensing Element: Precision organic polymer electrolytic film on ceramic substrate
- Housing Structure: Open-face protective bracket with solder terminals
- Terminal Pins: 2 × Gold-plated solder lead pins with 2.54 mm spacing
- Net Weight: Approx. 0.8 g
Dimensions:
- Substrate Length: 10.0 mm
- Substrate Width: 8.0 mm
- Overall Thickness: 3.0 mm
- Lead Pin Length: 10.0 mm
- Pin Pitch: 2.54 mm
Pinout and Wiring:
- Terminal 1: AC Excitation Signal Input (Apply symmetrical AC square wave or sine wave ~1V AC).
- Terminal 2: Output Signal (Connect in series with a precision fixed resistor to create an AC bridge circuit).
- Circuit Implementation Note: Like all electrolytic polymer humidity sensors, applying continuous DC voltage will cause rapid electrochemical migration and permanent sensor failure. Always drive using AC excitation.
Datasheet Reference:
- HDS10 Precision Condensation and Dew Sensor Component Specification & AC Bridge Circuit Integration Manual.
Commonly Used in:
- Professional video cameras, DSLR optical viewfinders, and broadcast lens defogging systems.
- Optical pick-up heads, DVD/Blu-ray players, and laser barcode scanning units.
- Industrial air conditioning units, heat pump heat exchangers, and commercial dehumidifiers.
- Automotive windshield defrosters, headlamp anti-fog modules, and cold-chain refrigerated transport.
Applications:
- Optical Lens Dew Protection: Shutting down laser heads or activating mini heating elements before moisture condenses on glass prisms.
- Cold-Storage Defrost Control: Sparing refrigeration compressors by activating defrost heaters only when actual condensation forms on coils.
- Electronics Enclosure Safety Cutoff: Preventing electrical short circuits in high-voltage industrial enclosures located in tropical, humid environments.
- Automated Mirror & Window Defogging: Triggering heating film on bathroom mirrors or vehicle mirrors when dew point is crossed.
Equivalent Models:
- HDS05 Condensation Sensor: Smaller form-factor variant with slightly higher baseline impedance.
- HR202L Resistive Sensor: Linear relative humidity sensor covering the whole 20% to 95% RH band rather than threshold dew detection.
- SHT40 Dew-Point Calculated Sensor: Digital I2C sensor measuring RH and temperature to compute mathematical dew point.
Package Includes:
- 1 × HDS10 Condensation Sensor

Reviews